MPPT charge controller calculator: Find the best solar charge controller for your system.

MPPT solar charge controllers are rated in amps (Output Current). To select a charge controller, you’ll need to calculate the maximum amount of current (in Amps) that the MPPT should be able to output.

This max output current value is calculated by dividing the maximum system wattage (in Watts) by the minimum charging voltage of the battery bank (in Volts).

In other words, we calculate how much current the solar charge controller needs to be able to put out by using this simple formula:

MPPT amperage rating = (Max. System Wattage) / (Min. Battery Charging Voltage)

However, MPPT charge controllers also have a Maximum Input Voltage rating, which indicates the maximum amount of voltage (in Volts) that is acceptable at the input of the MPPT.

So, when selecting your solar charge controller, you should account for both current and voltage.

But, don’t worry! I got you covered…

To make your life easier, I’ve made an MPPT size calculator that will do all the heavy lifting and give you a direct link to the charge controller best suited for your needs.

Below the MPPT calculator, I’ll give you 3 examples of different size solar arrays and battery banks that’ll illustrate this for you.

Also if you want a more in-depth understanding of how the calculator works, please refer to our MPPT sizing guide.

MPPT Size Calculator

The MPPT calculator has 6 input fields that will describe your solar energy system:

1- Solar panel wattage: This is the watts rating on each of your solar panels.

2- Solar panel open-circuit voltage (Voc): You can find this value in the specification label on the back of your solar panels, or by looking up the specific model.

3- Battery bank voltage (Nominal Voltage): The voltage of each battery is usually written on the casing. If you have more than one battery, the voltage of the battery bank is equal to the voltage from one string of batteries (series).

4- Lowest temperature during sunlight hours: In this field, you should enter the lowest value of temperature that you estimate your solar panels are ever going to be exposed to.

5- Number of strings: In your solar array, how many parallel strings are there?

6- Number of solar panels in each string: In each string, how many solar panels are wired in series?

As promised, below you’ll find a few examples that’ll clear things up for you.

Example 1: 200W-12V solar array with a 12V battery bank

For the first example, we have 2 100W-12Vwatts solar panels, these panels are wired in series and need to charge a 100Ah-12V Battle Born battery.

MPPT calculator - MPPT for 2 12V-100W solar panels in series feeding a 12V battery bank

Now we need to select the right size MPPT charge controller for this system.

So what do we know so far?

  • We have 2 100W-12V solar panels wired in series.
  • Our battery bank’s voltage is 12V nominal.

We still need 2 pieces of information:

  • The open-circuit voltage (Voc) on these panels.
  • The lowest temperature these panels will be exposed to.

As mentioned above, the manufacturer specifies 22.3V as the open-circuit voltage for each of these panels.

The lowest temperature in our example is -3°F.

Now that we have all the information we need, let’s take a look at the results from the MPPT calculator.

MPPT calculator - What size MPPT for 2 12V-100W solar panels in series feeding a 12V battery

The MPPT calculator tells us that our solar charge controller needs to have a maximum voltage input of more than 53V, and needs to be able to put out 22.5 amps.

The calculator also gave us links to 2 choices for MPPT charge controllers that meet these criteria.

Example 2: 400W-24V solar array with a 12V battery bank

For the 2nd example, we have 4 100W-12V solar panels, these panels are wired in 2S2P (2 parallel strings with 2 solar panels in each string).

These panels need to charge 2 parallel wired 100Ah-12V batteries.

MPPT Calculator - MPPT for 4 12V-100W solar panels in series-parallel feeding a 12V battery bank

So what we know is:

  • We have 2 parallel strings.
  • 2 solar panels in each string.
  • The power rating of our solar panels is 100W.
  • The open-circuit voltage of our solar panels is 22.3V.
  • The voltage of our battery bank is 12V.
  • The lowest temperature is -3°F.
MPPT calculator - What size MPPT for 4 12V-100W solar panels in series-parallel feeding a 12V battery bank

For this system, the MPPT calculator suggests a Victron 100V-50A charge controller and an EPEVER 50 amp charge controller.

Both of these charge controllers can handle the anticipated 53 Volts at their input and can put out up to 50 Amps of current.

Example 3: 200W-24V solar array with a 24V battery bank

For the third example, we have 4 100W-12V solar panels. And same as the 2nd example, these panels are wired in 2S2P.

However, the solar panels in this system need to charge 2 series wired 100Ah-12V batteries.

MPPT calculator - MPPT for 4 12V-100W solar panels in series-parallel feeding a 24V battery bank

So for this example:

  • We have 2 parallel strings.
  • 2 solar panels in each string.
  • The power rating of our solar panels is 100W.
  • The open-circuit voltage of our solar panels is 22.3V.
  • The voltage of our battery bank is 24V.
  • The lowest temperature is -3°F.

 

MPPT calculator - What size MPPT for 4 12V-100W solar panels in series-parallel feeding a 24V battery bank

Related topics:

What size wire between solar panels and MPPT?

What size wire between the MPPT and the battery?

Solar panels in series and in parallel – What is the difference?

What size fuse between solar panels and MPPT?

What size fuse between the MPPT and battery?

Spread knowledge... It's FREE!!
Avatar photo
Younes

Hi! My name is Younes. I'm an electrical engineer and a renewable energy enthusiast. I created renewablewise.com with a mission of delivering digestible content and information to the people who seek it.

Leave a Reply

Your email address will not be published. Required fields are marked *